77
XMEGA A [MANUAL]
8077I–AVR–11/2012
6.8.3
STROBE – Strobe register
If the STROBE register location is written, each event channel will be set according to the STROBE[n] and corresponding
DATA[n] bit settings, if any are unequal to zero.
A single event lasting for one peripheral clock cycle will be generated.
6.8.4
DATA – Data register
This register contains the data value when manually generating a data event. This register must be written before the
Table 6-6.
Digital filter coefficient values .
DIGFILT[2:0]
Group Configuration
Description
000
1SAMPLE
One sample
001
2SAMPLES
Two samples
010
3SAMPLES
Three samples
011
4SAMPLES
Four samples
100
5SAMPLES
Five samples
101
6SAMPLES
Six samples
110
7SAMPLES
Seven samples
111
8SAMPLES
Eight samples
Bit
76543210
+0x10
STROBE[7:0]
Read/Write
R/W
Initial Value
00000000
Bit
7654
3210
+0x11
DATA[7:0]
Read/Write
R/W
Initial Value
0000